Systems HPLC
Contact Details Tell a Colleague about this site Download Brochures in PDF Format Employment Opportunities at Cecil Training Distributors Site Map Service A Brief History of Cecil Instruments
 
IonQuest
HPLC
Spectrophotometers
Analysers
Automated Dissolutions
Reflectance
Accessories
Adept Menu
About HPLC
Systems
Isocratic Preparative
Columns
Accessories
Specification
Ordering
Ordering Systems
 
Powerstream
About Powerstream
Data Processing
Gradient Control
System Requirements

 

Adept System 1 : Anlytical Isocratic

This simple system is ideal for routine isocratic separations and quality assurance applications. High sensitivity is provided by the Adept CE4201 UV visible variable wavelength detector and precise delivery of the mobile phase is provided by the Adept CE4100 solvent delivery pump.

The Adept CE4100 dual piston pump provides flow rates from 0.001 to 10mL/min with a maximum operating pressure of 40MPa. The pump head is constructed with ceramic inserts to provide bio- compatibility.

The CE4201 UV-visible detector operates over the wavelength range 190nm-700nm with automatic fast second order filter insertion at 370nm. With noise of ± 0.5 x 10-5A peak to peak at 240nm and drift, at temperature equilibrium, typically ± 2 x 10-5A/hour, the new Adept UV visible detectors offer the highest performance available.

 
     
A column-mounting panel, which carries the Rheodyne injection valve, allows close coupling of the column to the flowcell for minimum dead volume. The standard flowcell, 8µL x 10mm pathlength, may be preceded by a heat exchanger for ultimate performance, if required. Chromatograms may be plotted on a pen recorder or an integrator. The system may be upgraded to provide data processing. The system is supplied complete with solvent and pipe organiser CE4033 and installation kit 4150 01 00.
 

     

Adept System 2 : Analytical Isocratic with Data Processing

This system uses the Adept CE4100 dual piston pump and the Adept CE4200 dual wavelength detector for added flexibility and is provided with PowerStream data processing software and interface unit, CE4901. The interface unit is placed at the base of the stack for convenience and minimum space requirement.

The CE4901 PowerStream software operating in Windows 98, 2000 or later versions, offers the same data processing power as the CE4900 software but unlike the latter, offers no system control. The system is supplied complete with solvent and pipe organiser CE4033, 8µL x 10mm pathlength cell and installation kit 4150 01 00.

As an alternative the CE 4900 PowerStream system with full system control, could be used allowing for expansion of the system at a future date.

 
     

     

ADEPT SYSTEM 3 : Automatic Analytical Isocratic

Routine analysis of large numbers of samples may be carried out using this system which requires minimum operator attention. System control and data processing is provided by PowerStream software and interface CE4900. The elegant, powerful and very easy to use software operates in Windows 98, 2000 or later versions.

The CE4800 automatic sample injector accommodates up to 96 samples, uses a Rheodyne injection valve, and offers a wide flexibility of sampling, analysis, delay and wash volumes.

 
     

The system uses the Adept CE4100 dual piston analytical pump head with delivery speeds from 0.001 to 10mL/min.

The detector is the Adept CE4200 dual wavelength monitor with a low noise level of less than ± 0.5 x 10-5A peak to peak and incredibly low drift of ± 2 x 10-5A/ hour at temperature equilibrium. The standard 8µL x 10mm flowcell is supplied but other cells may be used. The system is supplied complete with solvent and pipe organiser CE4033 and installation kit 4500 01 01.

 

     

ADEPT SYSTEM 4 : Analytical Binary Gradient

This gradient analytical system is shown here together with a column oven which must be ordered extra if required.

Two Adept CE4100 dual piston pumps, with flow rates from 0.001 to 10mL/min and a maximum operating pressure of 40MPa, are used with a dynamic mixer CE4120.

The Adept dual wavelength UV-visible detector CE4200 is used with an 8µL x 10mm flowcell. A column-mounting panel fitted to the detector carries the columns and the Rheodyne injector valve which is complete with a 20µL loop. A cover for the column is provided.

At the bottom of the stack, shown here, is the interface unit of the CE4900 PowerStream system manager. The software provides full system control and data processing using the latest versions of MS-Windows.

 
     
Results may be printed on any printer supported by the Windows operating system. The system is supplied complete with solvent and pipe organiser CE4033 and installation kit 4150 02 00.
 

     

ADEPT SYSTEM 5 : Analytical Ternary Gradient

The ternary gradient system uses three Adept CE4100 pumps, each providing flow rates from 0-001-10mL/min. A dynamic mixer CE4130 is provided with the system. For minimum space use, the system may be stacked vertically, as shown. A lower profile configuration is also shown in the picture below.

 

     
The Adept CE4200 dual wavelength, programmable, scanning detector is supplied with an 8µL x 10mm flowcell. The detector is fitted with the column-mounting panel which carries the Rheodyne injection valve with a 20µL loop. The solvent bottle and pipe co-ordinator, CE4033, is supplied and the system is complete with the installation kit 4150 03 00.   The PowerStream system manager, CE4900, is supplied for full system control and data processing. The software operates in Windows 98, 2000 or later versions. The interface unit is designed to mount at the top or bottom of the stacks as shown.
 

     

ADEPT SYSTEM 6 : Automatic Analytical Binary Gradient

This binary gradient system uses a conveniently small amount of space.

Two Adept CE4100 pumps are stacked on top of the CE4900 PowerStream system manager interface. These pumps each deliver at flow rates of 1-001 to 10mL/min and are connected to a dynamic mixer CE4120 placed on top of the dual wavelength detector CE4200 which is stacked above the pumps.

The system stack is topped by the solvent bottle and pipe co-ordinator CE4033 which mounts on top of the detector with the dynamic mixer beside it.

The automatic sample injector CE4800 completes the system. The sampler is fitted with a Rheodyne valve with 20µL loop and carries up to 96 samples.

 
     

The very high performance of the detector with exceptionally low drift provides a very stable system for extended measurements. Full system control and data processing are provided by the PowerStream system manager and software.

The system is supplied complete with installation kit 4150 02 01.

     

     

ADEPT SYSTEM 7 : Binary Gradient - Low Cost

This system offers the lowest cost binary gradient system. Consisting of two Adept CE4100 pumps with analytical heads providing flow rates from 0.001-10mL/min. controlled by the Adept CE4201 variable wavelength detector.

Gradients may be set from the control panel of the Adept CE4201 detector which allows up to 10 timed events to be programmed. An 8µL x 10mm pathlength cell is provided.

The system may be used with a pen recorder for economy, but may be upgraded at a latter date by the addition of a PowerStream system manager with data processing, if required.

 
 

     

ADEPT SYSTEM 8 : Ion Chromatography

A wide range of applications is possible with this flexible isocratic system. Single column ion chromatography or methods requiring a suppressor module are both possible.

The sensitive conductivity detector, CE4710 with twelve ranges from 0.01µS to 5000µS, houses the measuring cell in a thermostatted environment and the suppressor module CE4715 is available but not provided.

 
     

Solvent delivery is by the CE4100 dual piston pump. A Rheodyne injection valve is provided fitted with a 100µL loop. A CE4600 chilled and heated column oven is supplied, also a CE4033 solvent bottle and pipe guide organiser.

Data processing and system control are provided by the CE4900 interface and software. Installation kit 4150 05 00 is supplied with the system.

For increased sensitivity a solid phase chemical suppressor module CE4715 is available.

 

 
  About | Systems | Instruments | Columns | Ion Chromotography | Specification | Ordering | Ordering Systems
About PowerStream | Data Processing | Gradient Control | System Requirements