Accurate Quantification

For optimum accuracy when measuring concentration, a calibration line may be fitted to a series of up to 30 standards or replicates. Accuracy is improved over using a single known concentration or entering a factor.

     

Concentration Curve Fitting

When concentration is not linearly related to absorbance a quadratic or cubic curve may be fitted to up to 30 standards or replicates, with or without an intercept. A straight line may be fitted when a linear relationship exists. Curves are displayed with data for each standard documented.

     
     

Editing Of Data

Suspect standards revealed by the initial fit may be deleted or replaced for a new fit. Up to 30 curves may be stored security protected.

     

Wavelength Scanning

Wavelength scanning from 190-1000nm is standard on Super Aurius instruments with a narrow 1.8nm optical bandwidth. For the Aurius range scanning software is optional with a 4nm optical bandwidth.

Scans at up to 4000nm/min are displayed with peaks and valleys tabulated and scans of up to 6 screen widths may be viewed by scrolling. Spectra may be printed on either the integral printer, as shown below, or an external printer.

The Super Aurius range offers in addition:
Derivative spectra, spectral storage and overlayed spectra and time plot as standard.

 
     

Cell And Wavelength Programming

A cell program software module enables up to 4, 6 or 8 cells to be programmed with the appropriate cell changers. Programming of up to 10 different wavelengths is also provided by the wavelength program software module.

A combined cell and wavelength program may be run for up to 8 cells and 10 wavelengths. A cell and wavelength program may be used for calculations using complex formulae entered using the Assay program, with automatic formatting and printout of results.

     
 
 