Aquarius Menu
About Aquarius
Integral Software
Full Reference Beam Space
Display Scrolling of Scans
Optical Bandwidth
Versatility
Scanning
Quantitation
System Functions
Sampling
Validation Procedures
Software Modules
Specification
Accessory Range
Ordering Instruments
Ordering Accessories

Software Enhancement By E-SEF

This unique design feature - Encoded Software Enhancement Facility - provided by Cecil Instruments, enables any required additional software module to be released by an encoded entry. The encoded entry required is obtained by telephone, fax or E-mail, enabling you to expand your library of methods, without delay, when a new application arises within your laboratory.

Method Operation

Any procedure may be stored as a method in the security code protected integral memory of the Aquarius instruments. When a method is recalled, all instrument parameters are automatically set, without operator intervention, thus ensuring that the original conditions are exactly replicated.

Scan Storage

Scans, plots and curves may all be stored, for future use, with confidence in the integrity of the data. Integral memory is provided for up to 100 scans, protected by the operator’s personal security codes.

Reprocessing

Although scans may be in absorbance, transmittance or derivative format, any scan may be transformed to an alternative format by the very rapid reprocessing facility provided.

 

The screens shown are not two separate displays but part of a continuous display viewed by scrolling

     

Fully Documented Scans

As shown, all scans are fully documented on screen and in hard copy. Tables of all peaks and valleys are produced together with instrument, sample and operator details. Scans recalled from the instruments integral memory or by dynamic scan recall are also fully documented.

     

Benefits

Variable or Fixed Bandwidth
Large Backlit LCD Screen
Scrolled Screen Width 430mm
Dynamic Scan Recall
Full Reference Sample Space
Method Storage
Spectral Storage
Curve Storage
Password Protected Storage
Multi/Single Cell Kinetics
UV Lamp 1500 hours Guarantee

 

Performance

Bandwidth < 2nm or 0.5, 1, 2, 4nm variable
Stability ±0.0001A/H
Scan rate to 4000nm/min
Wavelength Precision 0.1nm
Straylight < 0.02%
Validation Software

   
 