Integral Software Spectrophotometers > Double Beam > Aquarius
Contact Details Tell a Colleague about this site Download Brochures in PDF Format Employment Opportunities at Cecil Training Distributors Site Map Service A Brief History of Cecil Instruments
 
IonQuest
HPLC
Spectrophotometers
Analysers
Automated Dissolutions
Reflectance
Accessories
Aquarius Menu
About Aquarius
Integral Software
Full Reference Beam Space
Display Scrolling of Scans
Kinetics / TD / Micro Samples
Scanning
Quantitation
System Functions
Sampling
Validation Procedures
Software Modules
Specifications
Ordering Instruments
Ordering Accessories
`

Software Enhancement by E-SEF

This unique design feature - Encoded Software Enhancement Facility - provided by Cecil Instruments, enables any required additional software module to be released by an encoded entry. The encoded entry required is obtained by telephone, fax or E-mail, enabling you to expand your library of methods, without delay, when a new application arises within your laboratory.

Method Operation

Any procedure may be stored as a method in the security code protected integral memory of the Aquarius instruments. When a method is recalled, all instrument parameters are automatically set, without operator intervention, thus ensuring that the original conditions are exactly replicated.

Scan Storage

Scans, plots and curves may all be stored, for future use, with confidence in the integrity of the data. Integral memory is provided for up to 100 scans, protected by the operators personal security codes.

Reprocessing

Although scans may be in absorbance, transmittance or derivative format, any scan may be transformed to an alternative format by the very rapid reprocessing facility provided.

 

The screens shown above are not two separate displays but part of a continuous display viewed by scrolling.

 

Fully Documented Scans

As shown below all scans are fully documented on screen and in hard copy.

Tables of all peaks and valleys are produced together with instrument, sample and operator details. Scans recalled from the instruments integral memory or by dynamic scan recall are also fully documented.

     

Benefits

Large Backlit LCD Screen
Screen Scrolling
Scrolled Screen Width 550mm
Dynamic Scan Recall
Full Reference Sample Space
Method Storage
Spectral Storage
Curve Storage
Code Protected Storage
Multi/Single Cell Kinetics
UV Lamp 1500 hours Guarantee

 

Performance

Bandwidth <2nm
Stability ±0.0001A/H
Scan rate to 4000nm/min
Wavelength Precision 0.1nm
Straylight 0.01%
Validation Software
Traceable Standards

     
 
  About | Integral Software | Beam Space | Displays | Kinetics : TD : MicroSamples | Scanning | Quantitation
System Functions | Sampling | Validation Procedures | Software Modules | Specifications
Ordering Instruments | Ordering Accessories