Powerful Quantification

Many quantitative methods are available including band area computation with background correction, differencing and stripping of spectra, wine and colour assays, mathematical calculations between several wavelengths, protein and DNA assays.

Curve and Line Fitting

A straight line, quadratic or cubic concentration curve may be fitted to up to 30 standards, with or without an intercept at the origin. Standards may be deleted and replaced and a new curve fitted.

Reaction Kinetics

Single cell kinetic measurements are possible with plots and data displayed on screen. Data may be reprocessed, regression analysis applied and curves stored, security code protected against tamper or deletion.

Multi-Cell Reaction Kinetics

Up to four or six cells are automatically measured with all reaction curves displayed on screen. Each curve may be selected for processing with the results of regression analysis printed.

Multi Wavelength Assays

Assays are provided using either two or three wavelengths. A wine colour assay is provided which may use up to ten different wavelengths. Computations at up to four wavelengths are also provided.

DNA and Protein Assays

Protein assays may be made using either the 2 or 3 wavelength methods of Warburg and Christian. Also programmed are techniques and analytical procedures for assays by Lowry, Bradford, Biuret and BCA methods.


Band Area and Height Computation

Band areas with correction for sloping background absorption are readily quantified, with all details and construction displayed. Band areas may also be computed for derivative spectra to facilitate difficult quantification.

Cell Program

Using the various cell changers, measurements may be made on up to 4, 6 or 8 cells at a single wavelength with cycle time and number of cycles entered by the operator. A cell and wavelength program may be combined.

Wavelength Program

Measurements may be programmed for 10 different operator selected wavelengths with the cycle time and number of cycles selected by the operator. A wavelength and cell program may be combined.

 