Specification Spectrophotometers > Double Beam > SuperAquarius
Contact Details Tell a Colleague about this site Download Brochures in PDF Format Employment Opportunities at Cecil Training Distributors Site Map Service A Brief History of Cecil Instruments
 
IonQuest
HPLC
Spectrophotometers
Analysers
Automated Dissolutions
Reflectance
Accessories
SuperAquarius Menu
About SuperAquarius
Integral  Control
Data Transfer to Pc
Fast Program Assay
Reaction Kinetics
Optical Performance
Scanning
Quantitation
System Functions
Sampling
Performance Validation
Software Modules
Specifications
Ordering Accessories and Spares
Ordering Instruments

 

Detector End window high performance photomultiplier
Optical System   Symmetrical full double beam; coated optics
Monochromator   Modified Czerny-Turner, 1200 L/mm holographic grating
Wavelength Range and Accuracy   190-800nm; 900nm R option and CE 9500 : ±0.5nm
Wavelength Accuracy   ±0.1nm at deuterium 656.1nm peak
Wavelength Reproducibility   ±0.1nm
Resolution   1.8nm; - CE 9500 selectable 0.5, 1, 2 and 4 nm
Straylight   Less than 0.01% at 220nm and 340nm
Straylight - as Pharmacopeia using KCl   Absorbance greater than 2A at 200nm
Photometric Noise   0.00003A (500nm, 2s response, 0A) RMS
Photometric Reproducibility   Better than ±0.0001A, 500nm
Baseline Flatness   ±0.001A
Stability   Better than ±0.0001A/hour, 500nm
Display Screen LCD   Displays menus, spectra, curves, data etc.
Screen Display Scrolling   550mm viewing width for spectra, plots etc.
Scan Speeds   1-4000nm/second
Overlayed Spectra   Up to 8 spectra with or without offsets
Dynamic Scan Recall   The 8 most recent scans are held for recall
Photometric Readout   -0.3-3A; 0-200%T; 0-9999C
Photometric Accuracy   0.004A at 1A
Derivative Spectra   1st - 4th derivatives (1st - 6th CE 9500)
Kinetics, Single and Multi-Cell   Calculation of rate, with plot for up to 6 cells
Method and Data Storage   For 100 methods with data
Spectral Reprocessing   Spectral scans may be expanded, transformed or derivatised and replotted over any wavelength range
Quantitative Curve Fitting   Linear, quadratic or cubic to 30 standards
Cell and Wavelength programming   8 cells and 10 wavelengths in any combination
Assay Program   Program computation of user entered formulae
Storage With Password Security   100 spectra, time plots and reaction curves
Alpha Numeric Text Entry   For annotation and formula entry
Sample Temperature Control   Single or multi-cell, water or thermoelectric
Micro Sipette Sampling   Under MPU control, with or without sample return
Real Time Clock   Timed and dated reports for GLP
Computer and Printer Interfaces   Bi-directional serial RS232c and parallel ports
   
Additional Specification : CE9500
 
Variable Resolution   0.5, 1, 2 and 4nm, variable optical bandwidth
Wavelength Range   190-900nm standard
Baseline   Full baseline for each bandwidth in safe memory
Derivative Spectra   1st to 6th derivatives
Turbid Sampling Optical System   Fitted standard, turbid sample holder provided
Precision Low Noise Measurement   Absorbance measurements with 0.1mA precision
Spectrofluorescence Measurements   Fluorescence accessory; Excitation wavelength scanning
Gel Scanning   Accessory available for 100mm gels
Size and Weight   805 x 410 x 196; 37Kg, 37.5Kg CE9500
Power Requirements   110-250V, 50/60Hz, 180W
 
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
 
  About | Integral Control | Data Transfer | Fast Program Assay | Reaction Kenetics | Optical Performance
Scanning | Quantitation | System Functions | Sampling | Performance Validation | Software Modules
Specifications | Ordering Instruments | Ordering Accessories