| The table shows a selection
of the most popular systems which when ordered come complete with
everything needed to make a fully working chromatographic system.
Degasser units should be ordered separately. |
| |
|
|
The systems listed provide... |
|
|
- All system modules
- Interconnection and power cables
- Pipes and tubing
- Solvent reservoir and pipe organiser
- Solvent bottles with drilled lids
- Standard flowcell
|
|
- Dynamic mixer
- Injection valve and loop (except automatic systems which have
their own)
- Column and valve panel where appropriate
- Sample injection syringe
- Solvent inlet filter
|
| |
|
|
Isocratic Systems |
|
|
| System |
Type |
Detector |
Auto
Sampler |
PowerStream |
Pump
CE4100 |
Variable
|
Dual
and Program |
DAD
Scanning |
50 |
100 |
Data and Control |
Data only |
| 1 |
Isocratic |
 |
|
|
|
|
|
|
 |
| 2 |
Isocratic |
|
 |
|
|
|
|
 |
 |
| 2S |
Isocratic, Scan |
|
|
 |
|
|
 |
|
 |
| 3 |
Isocratic, Auto |
|
 |
|
 |
|
 |
|
 |
| 3S |
Isocratic, Scan, Auto |
|
|
 |
 |
|
 |
|
 |
|
| |
|
|
| |
|
|
Binary Gradient Systems |
|
|
| System |
Type |
Detector |
Auto
Sampler |
PowerStream |
2
x Pump
CE4100 |
Variable
|
Dual
and Program |
DAD
Scanning |
50 |
100 |
Data and Control |
Data only |
| 4 |
Binary |
|
 |
|
|
|
 |
|
 |
| 4S |
Binary, Scan |
|
|
 |
|
|
 |
|
 |
| 6 |
Binary, Auto |
|
 |
|
 |
|
 |
|
 |
| 6S |
Binary, Scan, Auto |
|
|
 |
 |
|
 |
|
 |
|
| |
|
|
| |
|
|
Q-Adept Quaternary Systems - Low Pressure
Gradient |
| System |
Type |
Detector |
Auto
Sampler |
PowerStream |
Pump
CE4100-4 |
Dual
and Program |
DAD
Scanning |
50 |
100 |
| Q-4 |
Quaternary |
 |
|
|
|
 |
 |
| Q-4S |
Quaternary, Scan |
|
 |
|
|
 |
 |
| Q-6 |
Quaternary, Auto |
 |
|
 |
|
 |
 |
| Q-6S |
Quaternary, Scan, Auto |
|
 |
|
 |
 |
 |
|
| |
|
|
| |
|
|
Binary Systems - Low Pressure Gradient
|
| System |
Type |
Detector |
Auto
Sampler |
PowerStream |
Pump
CE4100-2 |
Dual
and Program |
DAD
Scanning |
50 |
100 |
| Q-2 |
Binary |
 |
|
|
|
 |
 |
| Q-2S |
Binary, Scan |
|
 |
|
|
 |
 |
| Q-3 |
Binary, Auto |
 |
|
 |
|
 |
 |
| Q-3S |
Binary, Scan, Auto |
|
 |
|
|
 |
 |
|
| |
|
|
| |
|
|
Ion Chromatography Systems |
| System |
Type |
Conductivity
Detector |
Heated
Oven |
Powerstream |
Auto
Sampler |
Suppressor |
Pump
CE4100 |
| 50 |
100 |
| C-1 |
Manual |
 |
 |
 |
|
|
|
 |
| C-2 |
Manual, Suppressor |
 |
 |
 |
|
|
 |
 |
| C-3 |
Suppressor, Auto |
 |
 |
 |
 |
|
 |
 |
|
| |
|
|
| |
|
|
Refractive Index Systems |
| System |
Type |
R1 Detector |
Heated Oven |
Powerstream
Data Only |
Auto
Sampler |
Pump CE4100 |
| 50 |
100 |
| R-1 |
Manual |
 |
|
 |
|
|
 |
| R-2 |
Auto |
 |
|
 |
 |
|
 |
|
| |
|
|
| |
|
|