1000 |
|
|
|
Super |
|
Aqua |
|
Bio |
|
Gene |
| |
|
Part Number and Narrative |
|
Series |
|
Aurius |
|
Aurius |
|
Quest |
|
Quest |
|
Quest |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 39 00
Ultra microcell holder for cells of 50ul working volume.
Use special cell part number 2020 07 01, UV grade silica,
10mm pathlength.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
4002 32 00
Dual water analysis sample holder designed to accommodate
both 10mm pathlength rectangular cuvettes and 16mm diameter
reaction tubes used with Merck SpectroQuant test kits. Time
is saved as the need to replace cell holders is eliminated.
|
|
No |
|
No |
|
No |
|
Yes |
|
No |
|
No |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 31 00
Holder for single 10mm pathlength cell.
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 39 00
Holder for cylindrical cells of pathlengths up to 100mm
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2021 30 00
Ultra microcell holder for cells with working volumes of
10ul (10mm pathlength, part number 202 07 64) and 5ul (5mm
pathlength, part number 202 07 63). Cells should be ordered
to suit individual circumstances. The holder provides high
precision alignment for maximum performance.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|


|
|
3021 37 00
Automatic cell changer for 8 cells for use in tablet dissolution
systems. The changer is supplied with a replacement cell compartment
lid and pipe guides. The changer is fully programmable when
used in conjunction with software Program C (Cell programming)
or controlled externally from PC.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 37 00
Holder for sipette/sip flowcells with pathlengths up to 50mm.
A retaining screw ensures that cells are securely retained
in the optimum position
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
1000 |
|
|
|
Super |
|
Aqua |
|
Bio |
|
Gene |
| |
|
Part Number and Narrative |
|
Series |
|
Aurius |
|
Aurius |
|
Quest |
|
Quest |
|
Quest |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 36 00
Holder for 4 cells with pathlengths up to 50mm. Must be used
in conjunction with 4 position manual cell changer (Part number
1010 34 00).
|
|
Yes |
|
No |
|
No |
|
No |
|
No |
|
No |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 31 20
Thermoelectric (Peltier) controlled cell holder for a single10mm
pathlength rectangular cell. Water circulation is provided
for heat removal when working at temperatures below ambient.
Used with CE2024 Thermoelectric Programmable Controller. Requires
1010 05 00 cell compartment lid and pipe guide.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2021 21 00
Return micro-sipette system comprising peristaltic pump and
mounting assembly, swan neck sample probe, sample probe mounting
block, all tubing and operating software. Sample volume size
may be programmed and samples saved for further analysis or
pumped to waste.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
1000 |
|
|
|
Super |
|
Aqua |
|
Bio |
|
Gene |
| |
|
Part Number and Narrative |
|
Series |
|
Aurius |
|
Aurius |
|
Quest |
|
Quest |
|
Quest |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 36 15
Water thermostatted cell holder for 4 x 10mm pathlength cells
shown fitted to automatic 4 cell changer (Part No. 2021 34
00) Automatic cell holder must be ordered separately. Requires
1010 05 00 Cell compartment lid and pipe guide.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2010 36 00
Cell holder for 4 cells of pathlengths from 20 to 40mm for
use with 4 position automatic cell changer (Part No. 2021
34 00). Cell changer musr be orderd separately.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

|
|
2021 34 00
Automatic changer for 4 cells. The photograph shows the cell
changer with a holder for 4 x 10mm pathlength cells which
is not included in the purchase price. The cell changer also
accomodates 2020 36 15 water thermostatted cell holder which
should be ordered to suit individual user requirements. When
used in conjunction with Software Program C, the cell changer
is fully programmable.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2021 24 00
Holder for 4 x 10mm pathlength rectangular cells for use
with automatic cell changer (Part No. 2021 34 00) which must
be ordered separately.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2021 34 00 with 2020 36 15
Automatic changer for 4 cells fitted with a water thermostatted
with holder for 4 x 10mm pathlength cells. Both items should
be ordered separately. When used with Software Program C the
cell changer is fully programmable. Requires 1010 05 00 cell
compartment lid and pipe guide.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1000 |
|
|
|
Super |
|
Aqua |
|
Bio |
|
Gene |
| |
|
Part Number and Narrative |
|
Series |
|
Aurius |
|
Aurius |
|
Quest |
|
Quest |
|
Quest |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2021 36 00
Automatic changer with integral holder for 6 x 10mm pathlength
rectangular cells. When used with Software Program C the cell
changer is fully programmable for speed and convenience.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 38 00
Manual microcell changer and holder for 4 cells. A beam focussing
system and 2 part sliding base allow optimum adjustment for
maximum light transmission for precise measurements.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 34 00 with 1010 24 00
Manual cell changer with holder for 4 x 10mm pathlength cells.
Changer and holder to suit individual application should be
ordered separately.
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 35 00
Water analysis manual cell changer and combined holder for
rectangular flowcells with pathlengths of 10, 20 and 40mm.
Cells of different pathlengths may be permanently mounted
in series in the holder. The cell most suited to the particular
application being undertaken may be selected and used. The
risk of breakage of expensive flowcells is significantly reduced.
Spacers are included for maximum flexibility in choice of
cell pathlength.
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
No |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 36 15
Water thermostatted cell holder for 4 x 10mm pathlength cells.
This holder should be used with manual 4 cell changer (Part
No. 1010 34 00) available at extra cost. Requires 1010 05
00 Cell compartment lid and pipe guide.
|
|
Yes |
|
No |
|
No |
|
No |
|
No |
|
No |
|
|
|
|
1000 |
|
|
|
Super |
|
Aqua |
|
Bio |
|
Gene |
| |
|
Part Number and Narrative |
|
Series |
|
Aurius |
|
Aurius |
|
Quest |
|
Quest |
|
Quest |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 02 00
Holder for a single 4 inch x 0.5 inch test tube
|
|
Yes |
|
No |
|
No |
|
No |
|
No |
|
No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 38 00
Holder for long pathlength rectangular cells up to 100mm
pathlength. Extended thumbscrews enable rapid and convenient
cell holder change.
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
1010 05 00
Cell compartment lid and pipe guide port for use with all
single beam spectrophotometer water thermostatting systems.
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
4002 34 00
Water analysis combination cell holder accepting both 16mm
reaction tubes and 1 inch square cells for convenience.
|
|
No |
|
No |
|
No |
|
Yes |
|
No |
|
No |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2010 32 00
Cell holder for single 10mm pathlength cell with sample stirring.
Must be used in conjunction with cell stirring controller
(Part No. 7200 31 01)
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2010 33 00
Cell holder for 10mm pathlength single cell with cell stirring
and water thermostatting. Must be used in conjunction with
cell stirring controller (Part No. 7200 31 01) and cell compartment
lid and pipe guide (Part No. 1010 05 00)
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
1000 |
|
|
|
Super |
|
Aqua |
|
Bio |
|
Gene |
| |
|
Part Number and Narrative |
|
Series |
|
Aurius |
|
Aurius |
|
Quest |
|
Quest |
|
Quest |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2010 34 00
Automatic cell changer for 4 x 10mm pathlength cells with
cell stirring and water thermostatting. Must be used in conjunction
with cell stirring controller (Part No. 7200 31 01) and cell
compartment lid and pipe guide (Part No. 1010 05 00). When
Software Program C is activated the cell changer is fully
programmable.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
7200 31 01
Electronic controller for sample stirring at speeds up to
1500 rpm. Must be used in conjunction with selected cell holder.
Choose from 2010 32 00, 2010 33 00 and 2010 34 00. Supplied
with a cell stirring bar.
|
|
No |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
|
|
|
Reflecta |
|
|
|
|
|
|
|
|
|
|
| |
|
Part Number and Narrative |
|
scan |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
CE3073
Integrating sphere with reference standard. A dedicated,
compact high performance Spectralon coated integrating sphere
is used for diffuse reflectance and diffuse transmission measurements.
The sphere unit has its own silicon diode detector using a
separate channel within the spectrophotometer. Use with CE3055
Reflectance Spectrophotometer
|
|
Yes |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
CE3075
Specular Reflectance Unit with flat sample rest, conical
lens mounting rest, mounted front surface aluminised plain
reference mirror and mounting thumb screws. This accessory
is used for the specular reflectance measurement of surfaces
and coated opthalmic lenses. It is ideally suited to quality
assurance in the production of anti-reflection coatings and
the measurement of thin film thickness.
|
|
Yes |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
CE3077
Opthalmic lens holder for transmission measurements with
lens centring, mounting plate and mounting thumb screws.
|
|
Yes |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
2020 33 00
Solid sample or film holder. Accepts samples up to 10mm thickness.
|
|
Yes |
|
|
|
|
|
|
|
|
|
|