Cells
  Aquarius   Super Aquarius
 

7200 30 00

Water analysis tube holder for 16mm reaction tubes as used with Merck Spectroquant test kits.

  Yes   Yes
             
 

7200 36 00

Ultra micro-cell holder for single cell of 10ul working volume with 10mm pathlength (Part No. 202 07 64) and 5ul working volume with 5mm pathlength (Part No. 202 07 63). Cells must be ordered separately.

  Yes   Yes
             
 

5500 34 00

Holder for 6 x 20mm pathlength rectangular cells. Requires automatic 6 cell changer (Part No. 9070 34 00)

  Yes   Yes
             
 

202 36 15

Water thermostatted cell holders for 4 x 10mm pathlength cells for use in both sample and reference beams. 2 holders are supplied for use with automatic 4 position cell changer (Part No. 9070 31 00) to be ordered separately.

  Yes   Yes
             
 

5500 36 15

Water thermostatted cell holder for 6 x 10mm pathlength cells. Requires 6 position automatic cell changer (Part No. 9070 34 00) to be ordered separately.

  Yes   Yes
             
 

202 36 16

Water thermostatted cell holder for 4 x 10mm pathlength cells. May be used in either sample or reference beams. Requires 4 position automatic cell changer (Part No. 9070 31 00) to be ordered separately.

  Yes   Yes
             

 

9070 31 00

Automatic cell changer for 4 x 10mm pathlength cells for either sample only or both sample and reference beams. Cell holders for appropriate cell pathlength should be ordered separately. The cell changer is fully programmable when used with Software Program C.

  Yes   Yes
    Narrative   Aquarius   Super Aquarius
 

503 36 00

Water thermostatted single cell holder for 10mm pathlength flowcell for use with return micro-sipette system (Part No. 7070 21 00 for Aquarius and 9070 21 00 for Super Aquarius) to be ordered separately.

  Yes   Yes
             
 

5500 33 00

Cell holder for 6 x 10mm pathlength cells. Must be used in conjunction with 6 position automatic cell changer (Part No. 9070 34 00)

  Yes   Yes
             
 

9070 58 00

Thermoelectrically (Peltier) controlled automatic cell changer with holders for both sample and reference beams. Water circulation is used for removing heat when working below ambient temperature. Must be used with thermoelectric controller (Part No. CE2024). When used with Software Program C the changer is fully programmable.

  Yes   Yes
             
 

9070 59 00

Thermoelectrically (Peltier) controlled automatic cell changer with holder for 6 x 10mm sample cells. Water circulation is used to remove heat when working below ambient temperature. When used with Software Program C the cell changer is fully programmable. Must be used with thermoelectric controller (Part No. CE2024)

  Yes   Yes
 

9070 57 00

Automatic cell changer and holder for 4 x 10mm pathlength sample cells with thermoelectric (Peltier) control. Water circulation is used to remove heat when working below ambient temperature. Must be used with thermoelectric controller CE2024 to be ordered separately. When used with Software Program C the cell changer is fully programmable.

  Yes   Yes
    Narrative   Aquarius   Super Aquarius
 

9070 54 00

Thermoelectrically (Peltier) controlled dual 10mm pathlength holder for sample and reference beams. Must be used with CE2024 thermoelectric controller to be ordered separately.

  Yes   Yes
             
 

503 26 00

Holder for single 10mm pathlength flowcell for use with sipette system (Part No. 9070 21 00) together with appropriate cell to be ordered separately.

  Yes   Yes
             
 

503 26 19

Universal cell holder for flowcells of 10 - 40mm pathlength for sipette systems. To be used with return micro- sipette system (Part No.7070 21 00 for Aquarius and 9070 21 00 for Super Aquarius spectrophotometers) to be ordered separately. Cells to suit individual requirements should be ordered additionally.

  Yes   Yes
             
 

9070 34 00

Automatic 6 cell changer. Holders for 10mm pathlength cells (Part No. 5500 33 00) or 20mm pathlength cells (Part No. 5500 34 00) should be ordered separately. Also used with water thermostatted 6 position cell holder (Part No. 5500 36 15). When used with Software Program C the cell changer is programmable.

  Yes   Yes
             
 

CE2024

Thermoelectric (Peltier) controller for precise control of sample and reference temperature.Temperature is set and controlled from the instrument keyboard and all reports will be annotated with the temperature set or programmed. Temperature range -10 to110C. Use with all spectrophotometers except Series 1000.

  Yes   Yes
             
 

7070 21 00

Micro-sipette system for Aquarius range spectrophotometers. Requires cell and holder to be ordered separately. Sample volume is set using the instrument keyboard and samples may be saved for further analysis or pumped to waste. May also be used in conjunction with a batch sampler.

  Yes   No
    Narrative   Aquarius   Super Aquarius
 

595 26 00

Holder for single cylindrical cells of up to 100mm pathlength.

  Yes   Yes
             
 

9070 21 00

Micro-sipette system for Super Aquarius spectrophotometers, requires cell and appropriate holder to be ordered separately. Sample volume may be set from the instrument keyboard and samples may be saved for further analysis or pumped to waste. May also be used in conjunction with a batch sampler.

  No   Yes
 

8020 56 00

Thermoelectrically (Peltier) controlled cell holder for single 10mm pathlength cell for use with CE2024 thermoelectric controller to be ordered separately. Water circulation may be used to remove heat when working below ambient temperature.

  Yes   Yes
             
 

8020 39 00

Ultra microcell holder for single 10mm pathlength cell of 50ul working volume. Use special cell (Part No. 2020 07 01) to be ordered separately.

  Yes   Yes
             
 

9070 31 00

Automatic cell changer for 4 x 10mm pathlength sample cells or 4 x 10mm sample and reference cells. Holders of desired pathlength should be ordered separately. May also be used with water thermostatted holders. When used in conjunction with Software Program C the cell changer is fully programmable.

  Yes   Yes
             
 

5500 34 00

Cell holder for 6 x 20mm pathlength rectangular cells. Must be used in conjunction with automatic 6 cell changer (Part No. 9070 34 00) not included.

  Yes   Yes
             
 

9070 39 00

Gel scanner for 100mm gels and films. Requires gel trough (Part No. 570 07 02) or autoradiograph film holder (Part No. 570 11 00) to be ordered separately.

  Yes   Yes
    Narrative   Aquarius   Super Aquarius
 

9070 32 00

Automatic changer and holder for 8 x 10mm pathlength cells for use with tablet dissolution systems.

  Yes   Yes
             
 

505 26 00

Standard cell holder for cells of 10 - 40mm for use in either sample or reference beams. Sold in pairs.

  Yes   Yes
             
 

CE575

Fixed angle reflectance accessory for sample and reference beams. Supplied as a pair.

  Yes   Yes
             
 

595 27 00

Holder for single rectangular cell up to 100mm pathlength. Cell to be ordered separately.

  Yes   Yes
             
 

CE572

Flourescence accessory enabling the excitation wavelength to be scanned. Filters are provided for emission radiation. Requires appropriate sample and reference cells to be ordered separately.

  No   Yes
             
 

CE574

Variable angle reflectance accessory. Particularly suited to the measurement of film thickness.

  No   Yes
             
 

8020 33 00

Film or solid sample holder

  Yes   Yes
             
 

7200 32 00

Electronic controller for sample stirring at speeds up to 1500 rpm. Supplied with 2 holders for 10mm pathlength cells for both sample and reference beams and 2 cell stirring bars. Cells to be ordered separately.

  Yes   Yes
             
 

7200 31 00

Electronic controller for sample stirring for sample beam only at speeds up to 1500 rpm. Supplied with a single 10mm cell holder and a cell stirring bar. Cell to be ordered separately.

  Yes   Yes
     
 