Cells Accessories > Cells
Contact Details Tell a Colleague about this site Download Brochures in PDF Format Employment Opportunities at Cecil Training Distributors Site Map Service A Brief History of Cecil Instruments
 
IonQuest
HPLC
Spectrophotometers
Analysers
Automated Dissolutions
Reflectance
Accessories
Accessories Menu
Single Beam Accessories
Double Beam Accessories
Cells
 
Rectangular Cells with lid
  mm   mm Prefix
External height 45 Internal width 10 UV grade silica 202
External width 12.5 Base thickness 1.5 Optical glass 303
         
Pathlength mm Working Volume ml Part no add prefix
1 0.25 - - - 07 23
2 0.5 - - - 07 24
5 1.3 - - - 07 25
10 2.5 - - - 07 26
20 5 - - - 07 27
40 10 - - - 07 28
50 12.5 - - - 07 29
100 25 - - - 07 71

 
Rectangular Cells with stopper
  mm   mm Prefix
External height 45 Internal width 10 UV grade silica 202
External width 12.5 Base thickness 1.5 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 1.3 - - - 07 35
10 2.5 - - - 07 36
20 5 - - - 07 37
40 10 - - - 07 39

 

 
Semi Micro Cells with with lids
  mm   mm Prefix
External height 45 Internal width 4 UV grade silica 202
External width 12.5 Base thickness 3 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 0.5 - - - 07 44
10 1 - - - 07 45
20 2 - - - 07 46
40 4 - - - 07 47

 
Semi Micro Cells Self Masking
  mm   mm Prefix
External height 45 Internal width 4 UV grade silica 202
External width 12.5 Base thickness 3 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 (typical) 0.5 - - - 07 40
10 1 - - - 07 41
20 2 - - - 07 42
40 4 - - - 07 43

 
Semi Micro Cells Self Masking Thick Base
  mm   mm Prefix
External height 45 Internal width 4 UV grade silica 202
External width 12.5 Base thickness 9 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 (typical) 0.3 - - - 07 56
10 0.6 - - - 07 57
20 1.2 - - - 07 58
40 2.4 - - - 07 59

 
Micro Cells with lids
  mm   mm Prefix
External height 45 Internal width 2 UV grade silica 202
External width 12.5 Base thickness 2.5 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 (used in our 4-cell 0.1 - - - 07 32
10 microcell holder) 0.2 - - - 07 33

 
Micro Cells Self Masking
  mm   mm Prefix
External height 45 Internal width 4 UV grade silica 202
External width 12.5 Base thickness 3 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 (used in our 4-cell 0.1 - - - 07 30
10 microcell holder) 0.2 - - - 07 31

 
Micro Cells with lids - self masking - thick base
  mm   mm Prefix
External height 45 Internal width 4 UV grade silica 202
External width 12.5 Base thickness 9 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
5 (typical) 0.3 - - - 07 34
10 0.6 - - - 07 38

 
Continuous Flow Microcells (Tablet Dissolution)
  mm   mm Prefix
External height 45 Internal width 4 UV grade silica 202
External width 12.5 Internal height 11 Optical glass 303
         
Pathlength mm Working Volume ml Part number add prefix
1 0.06 - - - 07 80
2 0.11 - - - 07 81
5 0.22 - - - 07 82
10 0.45 - - - 07 83
20 0.9 - - - 07 84

 
Micro Flow-Through Cells
(steam analysis, automatic sample changing, SIP sampling)
  mm   mm Prefix
External height 45 Internal diameter 3 UV grade silica 202
External width 12.5 Centre height 15 Optical glass 303
         
Pathlength mm Working Volume ul Part number add prefix
1 Typical 7 - - - 07 10
2 15 - - - 07 11
5 35 - - - 07 12
10 70 - - - 07 50
20 140 - - - 07 51
40 280 - - - 07 54

 
Micro-Sipette Low Volume Flowcell with screw connectors
  mm   mm Prefix
External height 45 Internal diameter 2 or 3 UV grade silica 202
External width 12.5 Beam cntr height 15 Optical glass 303
         
Pathlength mm Optical Volume ul Part number add prefix
10 20, ultra small 30 - - - 07 01
10 30, standard 70 - - - 07 02

 
Ultra-Microcell Cells with stoppers (bio-analysis)
  mm   mm Prefix
External height 45 Internal width 2 UV grade silica 202
External width 12.5 Beam cntr height 15  
 
Pathlength mm Filling Volume ul Part Number
10 180 202 07 17
10 120 202 07 16
10 70 202 07 15

 
Ultra-Microcell - Pipette Filling (Bio-analysis)
  mm   mm Prefix
External height 40 Internal diameter 0.8 UV grade silica 202
External width 12.5 Beam cntr height 15
           
Pathlength mm Filling Volume ul Part Number
5 5 202 07 63
10 10 202 07 64
Note: Use cell holder 2021 30 300 in Cecil Bioquest Spectrophotometer

 
Ultra-Microcell (Bio-analysis)
  mm   mm Prefix
External height 8 Internal width 2 UV grade silica 202
External width 12.5
           
Pathlength mm Working Volume ul Part Number
10 50 2020 07 01
Note: Use Cell Holder 2020 39 00 in single beam instruments e.g. BioQuest
Use Cell Holder 8020 39 00 for double beam instruments e.g.BioAquarius

 
Fluorescence Cells
  mm   mm Prefix
External height 45 Internal width 10 UV grade silica 202
External width 12.5 Base thickness 1.25
           
Pathlength mm Working Volume ml
Part Number
5 1.3
202 07 73
10 2.5
202 07 72
Note: One of each cell is required for the Cecil double beam fluorescence accessory

 
Cylindrical Cells with stoppers
  mm   mm Prefix
External height 32 Internal diameter 19 UV grade silica 202
External diameter 22 Optical glass 303
         
Pathlength mm Working Volume ml Part Number add prefix
50 14 - - - 07 65
100 28 - - - 07 66

 
Trough for Polyacrylamide Gels
  mm    
External height 11      
External width 100  
         
Pathlength mm     Part Number
5 Optical glass   570 07 01
5 UV grade silica
570 07 02
Note: For use with CE570 Gel Scanning Accessory

 

Magnetic Cell Stirrer

with speed display
100-1800 rpm, size 215 x 215 x 58mm

Control units are supplied with standard or water themostatted cell holders fitted with magnetic stirring heads, suitable for Cecil spectrophotometers; stirring bars are supplied.

Additional holders may be ordered and are interchangeable. Complete systems with controller are ordered as follows:

     
For Double Beam Spectrophotometers Standard Themostatted
Single cell holder 7200 31 00 7200 41 00
Sample and reference cell holders 7200 32 00 7200 42 00
4 Cell Holder 7200 33 00 7200 43 00
6 Cell Holder 7200 34 00 7200 44 00
     
For Single Beam Spectrophotometers    
Single Cell Holder 2041 31 00 2041 41 00
4 Cell Holder 2041 33 00 2041 43 00
     

 

Certified Validation Filters

Filters are available in calibrated sets for absorbance or wavelength calibration, or both.

All filters are of glass or silica glass formulation mounted in holders as shown here, with a height of 40mm and width of 12.5mm suitable for use in all normal cell holders.

The filter sets are supplied with calibration certificates issued by Cecil Instruments and traceable to NPL standards.

The nominal absorbance values of filters are given in the listing below.

         
    Part Number
4 Absorbance filters with certificate   0.25, 0.5, 1.0, 1.5A   594 44 00
6 Absorbance filters with certificate   0.25, 0.5, 1.0, 1.5, 2.0, 2.8A   594 66 00
2 Wavelength filters with certificates   Holmium and Didymium   303 40 00
4 Absorbance and 2 Wavelength filters with certificates   0.25, 0.5, 1.0, 1.5A
Holmium and Didymium
  594 88 00
6 Absorbance and 2 Wavelength filters with certificates   0.25, 0.5, 1.0, 1.5, 2.0, 2.8A
Holmium and Didymium
  594 77 00
Uncalibrated Wavelength filters   Holmium   202 01 44
    Didymium   303 01 30
 