 |
 |
 |
|
|
Rectangular Cells with lid
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
10 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
1.5 |
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part no add prefix |
|
1 |
|
0.25 |
- - - |
07 23
|
|
2 |
|
0.5 |
- - - |
07 24
|
|
5 |
|
1.3 |
- - - |
07 25
|
|
10 |
|
2.5 |
- - - |
07 26
|
|
20 |
|
5 |
- - - |
07 27
|
|
40 |
|
10 |
- - - |
07 28
|
|
50 |
|
12.5 |
- - - |
07 29
|
|
100 |
|
25 |
- - - |
07 71
|
|
|
|

|
|
Rectangular Cells with stopper
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
10 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
1.5 |
Optical glass |
303
|
| |
|
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number
add prefix |
|
5 |
|
1.3 |
- - - |
07 35
|
|
10 |
|
2.5 |
- - - |
07 36
|
|
20 |
|
5 |
- - - |
07 37
|
|
40 |
|
10 |
- - - |
07 39
|
|
|
| |
|

|
|
Semi Micro Cells with with lids
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
4 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
3 |
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
5 |
|
0.5 |
- - - |
07 44
|
|
10 |
|
1 |
- - - |
07 45
|
|
20 |
|
2 |
- - - |
07 46
|
|
40 |
|
4 |
- - - |
07 47
|
|
|
|

|
|
Semi Micro Cells Self Masking
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
4 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
3 |
Optical glass |
303
|
| |
|
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
5 |
(typical) |
0.5 |
- - - |
07 40
|
|
10 |
|
1 |
- - - |
07 41
|
|
20 |
|
2 |
- - - |
07 42
|
|
40 |
|
4 |
- - - |
07 43
|
|
|
|

|
|
Semi Micro Cells Self Masking Thick Base
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
4 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
9 |
Optical glass |
303
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
5 |
(typical) |
0.3 |
- - - |
07 56
|
|
10 |
|
0.6 |
- - - |
07 57
|
|
20 |
|
1.2 |
- - - |
07 58
|
|
40 |
|
2.4 |
- - - |
07 59
|
|
|
|

|
|
Micro Cells with lids
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
2 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
2.5 |
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
|
|
|
|
|
5 |
(used in our 4-cell |
0.1 |
- - - |
07 32
|
|
10 |
microcell holder) |
0.2 |
- - - |
07 33
|
|
|
|

|
|
Micro Cells Self Masking
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
4 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
3 |
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
5 |
(used in our 4-cell |
0.1 |
- - - |
07 30
|
|
10 |
microcell holder) |
0.2 |
- - - |
07 31
|
|
|
|

|
|
Micro Cells with lids - self masking - thick base
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
4 |
UV grade silica |
202
|
| External width |
12.5 |
Base thickness |
9 |
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
5 |
(typical) |
0.3 |
- - - |
07 34
|
|
10 |
|
0.6 |
- - - |
07 38
|
|
|

|
|
Continuous Flow Microcells (Tablet Dissolution)
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
4 |
UV grade silica |
202
|
| External width |
12.5 |
Internal height |
11 |
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part number add prefix |
|
1 |
|
0.06 |
- - - |
07 80
|
|
2 |
|
0.11 |
- - - |
07 81
|
|
5 |
|
0.22 |
- - - |
07 82
|
|
10 |
|
0.45 |
- - - |
07 83
|
|
20 |
|
0.9 |
- - - |
07 84
|
|
|
 |
|
Micro Flow-Through Cells
(steam analysis, automatic sample changing, SIP sampling)
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal diameter |
3 |
UV grade silica |
202
|
| External width |
12.5 |
Centre height |
15 |
Optical glass |
303 |
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ul |
Part number add prefix |
|
1 |
Typical |
7 |
- - - |
07 10
|
|
2 |
|
15 |
- - - |
07 11
|
|
5 |
|
35 |
- - - |
07 12
|
|
10 |
|
70 |
- - - |
07 50
|
|
20 |
|
140 |
- - - |
07 51
|
|
40 |
|
280 |
- - - |
07 54
|
|
|
 |
|
Micro-Sipette Low Volume Flowcell with screw connectors
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal diameter |
2 or 3 |
UV grade silica |
202
|
| External width |
12.5 |
Beam cntr height |
15 |
Optical glass |
303 |
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Optical Volume |
ul |
Part number add prefix |
|
10 |
20, ultra small |
30 |
- - - |
07 01
|
|
10 |
30, standard |
70 |
- - - |
07 02
|
|
|
 |
|
Ultra-Microcell Cells with stoppers (bio-analysis)
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
2 |
UV grade silica |
202 |
| External width |
12.5 |
Beam cntr height |
15 |
|
|
|
|
|
|
|
|
| Pathlength |
mm |
Filling Volume |
ul |
Part Number |
|
10 |
|
180 |
202 07 17 |
|
10 |
|
120 |
202 07 16 |
|
10 |
|
70 |
202 07 15 |
|
|
|

|
|
Ultra-Microcell - Pipette Filling (Bio-analysis)
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
40 |
Internal diameter |
0.8 |
UV grade silica |
202 |
| External width |
12.5 |
Beam cntr height |
15 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Pathlength |
mm |
Filling Volume |
ul |
Part Number |
|
5 |
|
5 |
202 07 63 |
|
10 |
|
10 |
202 07 64 |
| Note: Use cell holder
2021 30 300 in Cecil Bioquest Spectrophotometer |
|
|
 |
|
Ultra-Microcell (Bio-analysis)
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
8 |
Internal width |
2 |
UV grade silica |
202 |
| External width |
12.5 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Pathlength |
mm |
Working Volume |
ul |
Part Number |
|
10 |
|
50 |
2020 07 01 |
| Note: |
Use Cell Holder 2020 39 00 in single beam instruments
e.g. BioQuest
Use Cell Holder 8020 39 00 for double beam instruments e.g.BioAquarius |
|
|
 |
|
Fluorescence Cells
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
45 |
Internal width |
10 |
UV grade silica |
202 |
| External width |
12.5 |
Base thickness |
1.25 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part Number
|
|
5 |
|
1.3 |
202 07 73
|
|
10 |
|
2.5 |
202 07 72
|
| Note: One of each cell is required for
the Cecil double beam fluorescence accessory |
|
|
 |
|
Cylindrical Cells with stoppers
|
| |
mm |
|
mm |
|
Prefix
|
| External height |
32 |
Internal diameter |
19 |
UV grade silica |
202
|
| External diameter |
22 |
|
|
Optical glass |
303
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
Working Volume |
ml |
Part Number add prefix |
|
50 |
|
14 |
- - - |
07 65
|
|
100 |
|
28 |
- - - |
07 66
|
|
|
 |
|
Trough for Polyacrylamide Gels
|
| |
mm |
|
|
|
|
| External height |
11 |
|
|
|
|
| External width |
100 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Pathlength |
mm |
|
|
Part Number |
|
5 |
Optical glass |
|
570 07 01 |
|
5 |
UV grade silica |
|
570 07 02 |
| Note: For use with CE570 Gel Scanning Accessory |
|
|
 |
|
Magnetic Cell Stirrer
with speed display
100-1800 rpm, size 215 x 215 x 58mm
Control units are supplied with standard or water themostatted
cell holders fitted with magnetic stirring heads, suitable
for Cecil spectrophotometers; stirring bars are supplied.
Additional holders may be ordered and are interchangeable.
Complete systems with controller are ordered as follows:
|
| |
|
|
| For Double Beam Spectrophotometers |
Standard |
Themostatted |
| Single cell holder |
7200 31 00 |
7200 41 00 |
| Sample and reference cell holders |
7200 32 00 |
7200 42 00 |
| 4 Cell Holder |
7200 33 00 |
7200 43 00 |
| 6 Cell Holder |
7200 34 00 |
7200 44 00 |
| |
|
|
| For Single Beam Spectrophotometers |
|
|
| Single Cell Holder |
2041 31 00 |
2041 41 00 |
| 4 Cell Holder |
2041 33 00 |
2041 43 00 |
|
| |
|
|
|
 |
|
Certified Validation Filters
Filters are available in calibrated sets for absorbance or
wavelength calibration, or both.
All filters are of glass or silica glass formulation mounted
in holders as shown here, with a height of 40mm and width
of 12.5mm suitable for use in all normal cell holders.
The filter sets are supplied with calibration certificates
issued by Cecil Instruments and traceable to NPL standards.
The nominal absorbance values of filters are given in the
listing below.
|
| |
|
|
|
|
| |
 |
|
 |
Part Number |
| 4 Absorbance filters with certificate |
|
0.25, 0.5, 1.0, 1.5A |
|
594 44 00 |
| 6 Absorbance filters with certificate |
|
0.25, 0.5, 1.0, 1.5, 2.0, 2.8A |
|
594 66 00 |
| 2 Wavelength filters with certificates |
|
Holmium and Didymium |
|
303 40 00 |
| 4 Absorbance and 2 Wavelength filters with certificates |
|
0.25, 0.5, 1.0, 1.5A
Holmium and Didymium |
|
594 88 00 |
| 6 Absorbance and 2 Wavelength filters with certificates |
|
0.25, 0.5, 1.0, 1.5, 2.0, 2.8A
Holmium and Didymium |
|
594 77 00 |
| Uncalibrated Wavelength filters |
|
Holmium |
|
202 01 44 |
| |
|
Didymium |
|
303 01 30 |
|